HeartCalc / Neonatal echo

Neonatal Echo HemodynamicsExperimental

Targeted neonatal echo: LV and RV output, SVC flow, El-Khuffash and Iowa PDA scores, post-ligation LVO

Patient

Weight unitNo default: choose one

Flows are indexed to this weight. The El-Khuffash score's cohorts used birth weight for LV output; the Iowa score indexes PDA diameter to the weight on the day of the scan (the same in the first days).

LV output (aortic)

Diameter at the valve hinge points (parasternal long axis); VTI by pulsed Doppler (apical 5-chamber or suprasternal). One diameter and VTI per flow; average several beats.

RV output (pulmonary)

SVC flow (Kluckow and Evans)

Original method: maximal and minimal diameters by M-mode from a parasternal sagittal view where the SVC enters the right atrium (averaged over 3 cycles); VTI by pulsed Doppler at the SVC–RA junction from a low subcostal view. Area = π × (mean diameter)² / 4.

PDA severity score (El-Khuffash)

PDA present on this scan?

Narrowest diameter by 2D (not colour) at the pulmonary end; maximum shunt velocity; LV a′ by tissue Doppler at the lateral mitral annulus (apical 4-chamber; if e′ and a′ are fused, the single wave was recorded as a′). Uses the LV output above. Derived in infants <29 weeks on day 2.

Iowa PDA score (shunt volume)

Ductal shunt direction
Diastolic flow reversal in descending aorta, celiac or middle cerebral artery?

Also uses the PDA presence and diameter, weight, gestational and postnatal age, and LV and RV outputs entered above (no need to re-enter them). Definitions: E, peak early mitral inflow velocity by pulsed Doppler at the leaflet tips (apical 4-chamber); IVRT, aortic valve closure to mitral valve opening (apical 5-chamber, pulsed or tissue Doppler); D wave, peak diastolic pulmonary vein velocity at the vein's entry to the left atrium; LA:Ao, left atrial to aortic root diameter by M-mode (parasternal long axis, end systole); reversal, holodiastolic retrograde flow by pulsed Doppler in the post-ductal descending aorta, celiac artery or MCA. Velocities in cm/s (60, not 0.6). For left-to-right ducts in infants born <32 weeks, 12 h to 40 days.

Context

TAPSE is shown next to published neonatal reference values; no Z score is calculated (the reference equations could not be retrieved).

Related references

Model, equations and sources

Ventricular outputs and SVC flow

Flow [mL/kg/min] = VTI [cm] x π x (d [cm] / 2)^2 x HR [beats/min] / weight [kg]
LV output: d = aortic valve diameter, VTI = aortic VTI
RV output: d = pulmonary valve diameter, VTI = pulmonary VTI
SVC flow:  d = (maximal + minimal SVC diameter) / 2, VTI = SVC VTI

PDA severity score (El-Khuffash 2015)

Score = (GA [weeks] x -1.304) + (PDA diameter [mm] x 0.781)
      + (LV output [mL/kg/min] x 0.008) + (PDA Vmax [m/s] x -1.065)
      + (LV a' [cm/s] x -0.470) + 41

High risk of chronic lung disease or death: score ≥ 5

Iowa PDA score (shunt volume)

Iowa PDA score, current version (Brandt et al. 2025, Table 1, “adapted from Rios et al”)
Item0 points1 point2 points
Mitral valve E wave velocity, cm/s<45≥45 and ≤80>80
IVRT, ms>50≥30 and ≤50<30
Pulmonary vein D wave, cm/s<30≥30 and ≤50>50
Left atrium : aorta<1.3≥1.3 and ≤2.2>2.2
LVO : RVO<1.5≥1.5 and ≤2.5>2.5
Diastolic flow reversal in descending aorta and/or celiac and/or middle cerebral arteryno—yes
PDA diameter [mm] ÷ weight [kg]<1.5≥1.5 and ≤3>3
Total = sum of the 7 items (0 to 14)
<6   low-volume shunt
6-8  moderate-volume shunt
≥9   high-volume shunt ("above 8")

Post-ligation LV output (Jain 2012), cited context

Jain A, Sahni M, El-Khuffash A, et al. Use of targeted neonatal echocardiography to prevent postoperative cardiorespiratory instability after patent ductus arteriosus ligation. J Pediatr 2012;160(4):584-589.e1. doi:10.1016/j.jpeds.2011.09.027. Abstract: LV output <200 mL/kg/min at 1 hour after PDA ligation was a sensitive predictor of systemic hypotension and need for inotropes, and was used to start milrinone in the second epoch. The marker is shown only when the post-ligation box is ticked; it is not a treatment rule.

TAPSE references (displayed, not scored)

Not verified on this page

Computed in this browser; nothing you enter is stored or sent. Experimental: last checked against the cited sources October 2026.

Decision aid only. These measurements and scores do not replace clinical judgement.