One adult heart and circulation: four chambers, the systemic and pulmonary vessels and four valves. Each ventricle has a straight end-systolic line (ESPVR) and a curved, exponential end-diastolic curve (EDPVR). It is integrated in your browser and redrawn as it runs; a slider takes effect within the beat.
Ees is measured, not set: after each change the page runs a caval occlusion on a copy of the model and fits a line through the end-systolic points, as a catheter laboratory does. The button shows the same occlusion on the live loop.
It teaches how the end-systolic line, the end-diastolic curve and the arterial load set the loop, how the loop answers each, and what valve lesions and the two heart-failure phenotypes do to it. One modelled adult.
A closed circulation of lumped elements (Korakianitis & Shi 2006): left and right atria with their timed contraction, a systemic and a pulmonary bed each with a proximal and a distal artery (compliance, resistance, inertance), arterioles, capillaries and veins, and four valves that pass flow as an orifice, flow = CQ × √ΔP. Fourth-order Runge–Kutta, 0.1 ms steps; blood volume is conserved to rounding.
Each ventricle follows Ursino 1998 (Eq. 18): pressure = w(t) × Emax (V − Vu) + (1 − w(t)) × P0 (ekE V − 1), a straight end-systolic line blended with an exponential end-diastolic curve by an activation w from 0 to 1 (a squared half-sine over systole, Eq. 19), less an internal resistance that grows with pressure during ejection (Eq. 16–17). Systolic duration shortens with heart rate (Eq. 22). Table 2 gives both ventricles: LV Emax 2.95 mmHg/mL, Vu 16.77 mL, P0 1.5 mmHg, kE 0.014 /mL; RV Emax 1.75, Vu 40.8, P0 1.5, kE 0.011. Ursino had no human RV data: the RV elastance and volume and both internal resistances are scaled from dog data.
Choices of this page, not of the sources: the relaxation slider stretches the falling half of w, and when relaxation runs into the next beat the remainder carries over (incomplete relaxation); the pulmonary resistances of Korakianitis & Shi are scaled down so their total equals the sum of Ursino 1998 Table 1’s pulmonary resistances (0.118 mmHg·s/mL), because as printed they sum to 0.318, which at 5 L/min puts about 26 mmHg across the lungs; the blood volume is set for a cardiac output of 5 L/min, the normal Korakianitis & Shi give. Stenosis narrows the open orifice; regurgitation leaves the closed valve open by a fraction of its area (their Eq. 8 and Table 4: mitral stenosis opens to 23% of the normal area, aortic regurgitation leaks through 1.6%; the other sizes are illustrations).
| State | Published (source) | Model |
|---|---|---|
| Normal LV | Ees 2.1 ± 0.9 (normotensives), Ea 1.9 ± 0.5 mmHg/mL (comparison group not named) (Kawaguchi 2003, abstract); τ 35 ± 10 ms (Zile 2004, abstract); Ea/Ees about 0.6 (Bastos 2020, review) | Ees 2.81, Ea 1.68, Ea/Ees 0.60, τ 37 ms, EF 55%; cardiac output set to 5.0 L/min |
| Normal RV | EF 62 (6)%, loop triangular, ejection continuing as pressure falls (Redington 1988, abstract, 10 adults) | EF 56%; isovolumic time 17% of the beat against 30% in the LV; 10% of the RV stroke volume ejected after peak pressure against 3% in the LV |
| Caval occlusion | The ESPVR the law was given | With no internal resistance, Ees and V0 equal Emax and Vu exactly; with it, LV 2.81 (set 2.95), RV 1.49 (set 1.75) |
| HFpEF | Ees 4.7 ± 1.5, Ea 2.6 ± 0.5, EDP 24.3 ± 4.6 mmHg, similar stroke volume (Kawaguchi 2003, abstract); τ 59 ± 14 ms (Zile 2004, abstract); pacing at 120/min lowered stroke volume (Westermann 2008, abstract) | Fitted to all five (Emax, arterial compliance, EDPVR exponent, relaxation and blood volume, +281 mL); aortic pressure 186/40 mmHg (pulse pressure about 146), wider than in patients, because the whole rise in Ea was put into arterial compliance; at 120/min stroke volume falls from 69 to 58 mL, but the normal heart’s falls more (69 to 49) |
| HFrEF | EF under 40% with Ees under half of Ea (Asanoi 1989, abstract); Ea/Ees above 1.2 (Bastos 2020, review) | EF 22%, Ees 0.82, Ea 2.23, Ea/Ees 2.7 (an illustration) |
| Aortic stenosis, then TAVR | Medians before and after, 61 patients: Ea 2.66 → 1.96, Ees 2.22 → 1.58 mmHg/mL, SW 10,936 → 6,878 and PVA 17,832 → 11,025 mmHg·mL, SW/PVA stable (van den Enden 2026, abstract; units printed “mmHg/mL”) | Ea 2.66 and Ees 2.22 before (fitted; the live Ea reads 2.64 to 2.66, with the sample taken as end-systole); Ea 1.68 after; SW 9,480 → 6,906 and PVA 14,286 → 9,342, as in the cohort (values after a long settle: the live readouts differ in the last digits); SW/PVA 0.66 → 0.74 (cohort: stable) and measured Ees 2.22 → 2.69 (cohort: fell) |
| Mitral regurgitation, then repair | MitraClip in 33 patients: ESPVR not significantly changed, cardiac index up, pulmonary capillary wedge pressure 15 → 12 mmHg, PVA unchanged (Gaemperli 2013, abstract) | Illustration in a normal heart (regurgitant fraction 40%): forward output 4.4 → 5.0 L/min, mean left atrial pressure 8.1 → 6.3 mmHg, PVA 10,115 → 9,393 (the live readouts differ in the last digits), Ees 2.95 → 2.81 |
| Tricuspid regurgitation, then repair | End-diastolic volume and stroke volume fall and RV afterload rises with edge-to-edge repair, in one illustrated case (Brener 2022 Circ Heart Fail, review, Fig. 7C) | RV end-diastolic volume 134 → 125 mL, RV stroke volume 81 → 69 mL, RV Ea 0.27 → 0.33 mmHg/mL |
Experimental and not independently verified. There is no official calculator for a physiology model; the comparators are the published numbers above.
The model runs in this browser; nothing you set on this page is stored or sent.
Educational use only. A teaching model of one adult heart, not a patient-specific prediction and not a treatment recommendation.