Pressure-Volume Loop Simulator Experimental

1. The model running

Circulation
Ventricle

The ventricle on show and its load × the chosen state

Guided tour
Left ventriclepressure mmHg against volume mL
  • —— Loop now
  • - - - Loop kept for comparison, with its Ea line (fainter)
  • Abbreviations
Ejection fraction (EF)…
Stroke volume (SV)…
End-diastolic pressure (EDP)…
Ventricular-arterial coupling (Ea/Ees)…

2. What this shows, and what it cannot

It teaches how the end-systolic line, the end-diastolic curve and the arterial load set the loop, how the loop answers each, and what valve lesions and the two heart-failure phenotypes do to it. One modelled adult.

Model, equations and sources

What is being solved

A closed circulation of lumped elements (Korakianitis & Shi 2006): left and right atria with their timed contraction, a systemic and a pulmonary bed each with a proximal and a distal artery (compliance, resistance, inertance), arterioles, capillaries and veins, and four valves that pass flow as an orifice, flow = CQ × √ΔP. Fourth-order Runge–Kutta, 0.1 ms steps; blood volume is conserved to rounding.

Each ventricle follows Ursino 1998 (Eq. 18): pressure = w(t) × Emax (V − Vu) + (1 − w(t)) × P0 (ekE V − 1), a straight end-systolic line blended with an exponential end-diastolic curve by an activation w from 0 to 1 (a squared half-sine over systole, Eq. 19), less an internal resistance that grows with pressure during ejection (Eq. 16–17). Systolic duration shortens with heart rate (Eq. 22). Table 2 gives both ventricles: LV Emax 2.95 mmHg/mL, Vu 16.77 mL, P0 1.5 mmHg, kE 0.014 /mL; RV Emax 1.75, Vu 40.8, P0 1.5, kE 0.011. Ursino had no human RV data: the RV elastance and volume and both internal resistances are scaled from dog data.

Choices of this page, not of the sources: the relaxation slider stretches the falling half of w, and when relaxation runs into the next beat the remainder carries over (incomplete relaxation); the pulmonary resistances of Korakianitis & Shi are scaled down so their total equals the sum of Ursino 1998 Table 1’s pulmonary resistances (0.118 mmHg·s/mL), because as printed they sum to 0.318, which at 5 L/min puts about 26 mmHg across the lungs; the blood volume is set for a cardiac output of 5 L/min, the normal Korakianitis & Shi give. Stenosis narrows the open orifice; regurgitation leaves the closed valve open by a fraction of its area (their Eq. 8 and Table 4: mitral stenosis opens to 23% of the normal area, aortic regurgitation leaks through 1.6%; the other sizes are illustrations).

What is read off each beat

Checks

What the model was set to, and what came out against published numbers. Adult values.
StatePublished (source)Model
Normal LVEes 2.1 ± 0.9 (normotensives), Ea 1.9 ± 0.5 mmHg/mL (comparison group not named) (Kawaguchi 2003, abstract); τ 35 ± 10 ms (Zile 2004, abstract); Ea/Ees about 0.6 (Bastos 2020, review)Ees 2.81, Ea 1.68, Ea/Ees 0.60, τ 37 ms, EF 55%; cardiac output set to 5.0 L/min
Normal RVEF 62 (6)%, loop triangular, ejection continuing as pressure falls (Redington 1988, abstract, 10 adults)EF 56%; isovolumic time 17% of the beat against 30% in the LV; 10% of the RV stroke volume ejected after peak pressure against 3% in the LV
Caval occlusionThe ESPVR the law was givenWith no internal resistance, Ees and V0 equal Emax and Vu exactly; with it, LV 2.81 (set 2.95), RV 1.49 (set 1.75)
HFpEFEes 4.7 ± 1.5, Ea 2.6 ± 0.5, EDP 24.3 ± 4.6 mmHg, similar stroke volume (Kawaguchi 2003, abstract); τ 59 ± 14 ms (Zile 2004, abstract); pacing at 120/min lowered stroke volume (Westermann 2008, abstract)Fitted to all five (Emax, arterial compliance, EDPVR exponent, relaxation and blood volume, +281 mL); aortic pressure 186/40 mmHg (pulse pressure about 146), wider than in patients, because the whole rise in Ea was put into arterial compliance; at 120/min stroke volume falls from 69 to 58 mL, but the normal heart’s falls more (69 to 49)
HFrEFEF under 40% with Ees under half of Ea (Asanoi 1989, abstract); Ea/Ees above 1.2 (Bastos 2020, review)EF 22%, Ees 0.82, Ea 2.23, Ea/Ees 2.7 (an illustration)
Aortic stenosis, then TAVRMedians before and after, 61 patients: Ea 2.66 → 1.96, Ees 2.22 → 1.58 mmHg/mL, SW 10,936 → 6,878 and PVA 17,832 → 11,025 mmHg·mL, SW/PVA stable (van den Enden 2026, abstract; units printed “mmHg/mL”)Ea 2.66 and Ees 2.22 before (fitted; the live Ea reads 2.64 to 2.66, with the sample taken as end-systole); Ea 1.68 after; SW 9,480 → 6,906 and PVA 14,286 → 9,342, as in the cohort (values after a long settle: the live readouts differ in the last digits); SW/PVA 0.66 → 0.74 (cohort: stable) and measured Ees 2.22 → 2.69 (cohort: fell)
Mitral regurgitation, then repairMitraClip in 33 patients: ESPVR not significantly changed, cardiac index up, pulmonary capillary wedge pressure 15 → 12 mmHg, PVA unchanged (Gaemperli 2013, abstract)Illustration in a normal heart (regurgitant fraction 40%): forward output 4.4 → 5.0 L/min, mean left atrial pressure 8.1 → 6.3 mmHg, PVA 10,115 → 9,393 (the live readouts differ in the last digits), Ees 2.95 → 2.81
Tricuspid regurgitation, then repairEnd-diastolic volume and stroke volume fall and RV afterload rises with edge-to-edge repair, in one illustrated case (Brener 2022 Circ Heart Fail, review, Fig. 7C)RV end-diastolic volume 134 → 125 mL, RV stroke volume 81 → 69 mL, RV Ea 0.27 → 0.33 mmHg/mL

Sources

Verification

Experimental and not independently verified. There is no official calculator for a physiology model; the comparators are the published numbers above.

The model runs in this browser; nothing you set on this page is stored or sent.

Educational use only. A teaching model of one adult heart, not a patient-specific prediction and not a treatment recommendation.